V1/5 (A2) NDT Calibration Block

NDE offers calibration blocks and flawed specimens. Please browse our products to find the best one for you. If you have any questions about NDE and our V1/5 (A2) Calibration Blocks, please contact us at +91-9043-660-755 or send an email to info@ndeflawtechnologies.com.and to know more details about block and specimens log on to www.ndtproduct.com Our knowledgeable customer service staff is happy to assist you.
Sort By:  
dsr calibration block
DSR Calibration Block DSR Distance-Sensitivity-Resolution Calibration Block for Dual Probes. Designed to determine near surface resolution of dual thickness gauging probes and verify sensitivity of dual thickness gauges.
v15 block 7075 t6 aluminum a2 ndt ut calibration block
V1/5 (A2) Calibration Block 1018 Steel Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range. Dimensions: 300mm x 100mm x 25mm
v15 block 7075 t6 aluminum a2 ndt ut calibration block
V1/5 Block 304 Stainless Steel (A2) Block Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range. Dimensions: 300mm x 100mm x 25mm
v15 block 7075 t6 aluminum a2 ndt ut calibration block
V1/5 Block, 7075-T6 Aluminum (A2) Block Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range. Dimensions: 300mm x 100mm x 25mm
dsr calibration block
DSR Calibration Block (7020)

DSR Calibration Block

DSR Distance-Sensitivity-Resolution Calibration Block for Dual Probes.
Designed to determine near surface resolution of dual thickness gauging probes and verify sensitivity of dual thickness gauges.

Features include:
Four step (.250, .500, .750 and 1.000 inch) calibration block for distance calibration
Side drilled holes 0.030" (0.75 mm) diameter drilled with metal-path distance from 0.030" (0.75mm) to 1" (25 mm).
DSR Calibration Block DSR Distance-Sensitivity-Resolution Calibration Block for Dual Probes. Designed to determine near surface resolution of dual thickness gauging probes and verify sensitivity of dual thickness gauges.
v15 block 7075 t6 aluminum a2 ndt ut calibration block
V1/5 (A2) Calibration Block 1018 Steel (7243)

V1/5 (A2) Calibration Block 1018 Steel

Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range.
Dimensions: 300mm x 100mm x 25mm
In accordance with British Standard BS 2704 Block A2 Mod. 1, German Standard DIN 54-120, Australian Standard AS 2803, and ISO 2400.
V1/5 (A2) Calibration Block 1018 Steel Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range. Dimensions: 300mm x 100mm x 25mm
v15 block 7075 t6 aluminum a2 ndt ut calibration block
V1/5 Block 304 Stainless Steel (A2) Block (7244)

V1/5 Block 304 Stainless Steel (A2) Block

For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range. In accordance with British Standard BS 2704 Block A2 Mod. 1, German Standard DIN 54-120, Australian Standard AS 2803, and ISO 2400. Also meets the requirements of the Dassault Aviation Falcon 10 Mandatory Service Bulletin #294 dated March 20, 2002. 

This block is not to be confused with the new EN 12223/ ISO 2400 Calibration Block No. 1 (also called the K1 block,) which is similar but contains a 3.0mm through-hole rather than a 1.5mm hole. See our test block store for this block.

• Dimensions: 300mm x 100mm x 25mm
• Made from Type 304 Stainless Steel.
V1/5 Block 304 Stainless Steel (A2) Block Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range. Dimensions: 300mm x 100mm x 25mm
v15 block 7075 t6 aluminum a2 ndt ut calibration block
V1/5 Block, 7075-T6 Aluminum (A2) Block (7245)

V1/5 Block, 7075-T6 Aluminum (A2) Block

Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range.
Dimensions: 300mm x 100mm x 25mm
In accordance with British Standard BS 2704 Block A2 Mod. 1, German Standard DIN 54-120, Australian Standard AS 2803, and ISO 2400.
V1/5 Block, 7075-T6 Aluminum (A2) Block Geometry:100mm radius, 1.5mm and 50.0mm holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 100mm range. Dimensions: 300mm x 100mm x 25mm
Per Page      1 - 4 of 4