Search

Search Criteria

 
 
 
 

Products meeting the search criteria

Sort By:  
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM Distance Amplitude Set of 19-304 Stainless Steel ASTM E428 Area Amplitude Calibration Blocks, 304 Stainless Steel, Set of 19. Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM Distance Amplitude Set of 19-7075 Aluminum ASTM E127 Area Amplitude Calibration Blocks, 7075 Aluminum, Set of 19. Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM Distance Amplitude Set of 19-Titanium ASTM E428 Area Amplitude Calibration Blocks, Titanium, Set of 19 Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM Distance Amplitude Set of 19-4340 Steel ASTM E428 Area Amplitude Calibration Blocks, 4340 Steel, Set of 19. Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
eddy current tube standard iris
Internal Rotary Inspection System Tube Eddy Current Tube Standards. Ready to request a quote for a standard? Here's what we need... What is the material? (Alloy, OD and Wall) Is NDE supplying the material or will it be customer supplied? What defects are needed and what size? (most depths are given in % of tube wall) Is there a specification the standard needs to comply with? (ASME, etc.) If you have a drawing, or even a simple hand sketch, please send that along as well. We specialize in custom eddy current tubes, and have years of experience in machining a huge range of defects. From TWHs and FBHs, OD and ID grooves, milled flats, and OD and ID thinning bands, to ID FBHs, ID contoured flats, 120°/180° wearscars, tapered flaws, and tube-to-tube wear,
Ultrasonic Thickness Gauge NdeTech-UTG702 Functions & Features • Display: LCD with LED backlight .The brightness and the contrast of the LCD is adjustable. • Display contents: thickness value, coupling condition, power state, CAL calibration state, sound velocity. • Able to measure the ultrasonic velocity in turn if the thickness value is known in order to improve the measurement precision. • Zero adjustment: auto returning to zero when you press the key after the probe is put on the specimen. • Simply and easily operated. • Nonlinear correction, automatic compensation, in order to improve the measurement accuracy. • The test block of measuring sound velocity of known thickness. • Battery information indicates the rest capacity of the battery, Auto sleep and auto power off function to conserve battery life. • Optional software to process the memory data on the PC. • Alarm function: setting the measurement limit and alarming for the results beyond the limit.
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM Distance Amplitude Set of 19, 304 Stainless Steel (7091)

ASTM Distance Amplitude Set of 19, 304 Stainless Steel


Set of nineteen flat-bottom hole blocks used to determine the relationship between metal travel distance (MTD)and signal amplitude. All blocks have the same size flat-bottom hole and varying MTD. Hole diameter must be specified when ordering (3/64”, 5/64” or 8/64”). In accordance with ASTM E428. Includes our NIST traceable dimensional certification report, ultrasonic inspection report and response plot from Tactic Inc, and the certified material test report. Note that we use a 5.0 MHz quartz transducer for block characterization as required by ASTM E127, Section 11.
• Dimensions: Metal travel distances are: .063”, .125”, .250”, .375”, .500”, .625”, .750”, .875”, 1.000”, 1.250”, 1.750”, 2.250”, 2.750”, 3.250”, 3.750”, 4.250”, 4.750”, 5.250” and 5.750”. Block diameter is 2.0".
• Made from 304 Stainless Steel
ASTM Distance Amplitude Set of 19-304 Stainless Steel ASTM E428 Area Amplitude Calibration Blocks, 304 Stainless Steel, Set of 19. Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM Distance Amplitude Set of 19, 7075 Aluminum (7093)

ASTM Distance Amplitude Set of 19, 7075 Aluminum


Set of nineteen flat-bottom hole blocks used to determine the relationship between metal travel distance (MTD)and signal amplitude. All blocks have the same size flat-bottom hole and varying MTD. Hole diameter must be specified when ordering (3/64”, 5/64” or 8/64”). In accordance with ASTM E428. Includes our NIST traceable dimensional certification report, ultrasonic inspection report and response plot from Tactic Inc, and the certified material test report. Note that we use a 5.0 MHz quartz transducer for block characterization as required by ASTM E127, Section 11.
• Dimensions: Metal travel distances are: .063”, .125”, .250”, .375”, .500”, .625”, .750”, .875”, 1.000”, 1.250”, 1.750”, 2.250”, 2.750”, 3.250”, 3.750”, 4.250”, 4.750”, 5.250” and 5.750”. Block diameter is 2.0".
• Made from Type 7075 Aluminum.
ASTM Distance Amplitude Set of 19-7075 Aluminum ASTM E127 Area Amplitude Calibration Blocks, 7075 Aluminum, Set of 19. Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM Distance Amplitude Set, of 19-Titanium (7094)

ASTM Distance Amplitude Set, of 19-Titanium


Set of nineteen flat-bottom hole blocks used to determine the relationship between metal travel distance (MTD)and signal amplitude. All blocks have the same size flat-bottom hole and varying MTD. Hole diameter must be specified when ordering (3/64”, 5/64” or 8/64”). In accordance with ASTM E428. Includes our NIST traceable dimensional certification report, ultrasonic inspection report and response plot from Tactic Inc, and the certified material test report. Note that we use a 5.0 MHz quartz transducer for block characterization as required by ASTM E127, Section 11.
• Dimensions: Metal travel distances are: .063”, .125”, .250”, .375”, .500”, .625”, .750”, .875”, 1.000”, 1.250”, 1.750”, 2.250”, 2.750”, 3.250”, 3.750”, 4.250”, 4.750”, 5.250” and 5.750”. Block diameter is 2.0".
• Made from 6AL-4V Titanium.
ASTM Distance Amplitude Set of 19-Titanium ASTM E428 Area Amplitude Calibration Blocks, Titanium, Set of 19 Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
astm distance amplitude set 19 4340 steel ndt calibration block
ASTM, Distance Amplitude Set of 19, 4340 Steel (7092)

ASTM, Distance Amplitude Set of 19, 4340 Steel


Set of nineteen flat-bottom hole blocks used to determine the relationship between metal travel distance (MTD)and signal amplitude. All blocks have the same size flat-bottom hole and varying MTD. Hole diameter must be specified when ordering (3/64”, 5/64” or 8/64”). In accordance with ASTM E127. Includes our NIST traceable dimensional certification report, ultrasonic inspection report and response plot from Tactic Inc, and the certified material test report. Note that we use a 5.0 MHz quartz transducer for block characterization as required by ASTM E127, Section 11.
• Dimensions: Metal travel distances are: .063”, .125”, .250”, .375”, .500”, .625”, .750”, .875”, 1.000”, 1.250”, 1.750”, 2.250”, 2.750”, 3.250”, 3.750”, 4.250”, 4.750”, 5.250” and 5.750”. Block diameter is 2.0".
• Made from 4340 Steel.
ASTM Distance Amplitude Set of 19-4340 Steel ASTM E428 Area Amplitude Calibration Blocks, 4340 Steel, Set of 19. Geometry:Set of 19 blocks which contain hole diameters of 3/64", 5/64" or 8/64" with metal travel distances of: .06", .12",.25",.37",.50", .62",.75",.87",1.0",1.25", 1.75", 2.25", 2.75", 3.25", 3.75", 4.25", 4.75", 5.25" and 5.75".
eddy current tube standard iris
ET Calibration Tube Standards

Internal Rotary Inspection System Tube

Eddy Current Tube Standards. Ready to request a quote for a standard? Here's what we need... What is the material? (Alloy, OD and Wall) Is NDE supplying the material or will it be customer supplied? What defects are needed and what size? (most depths are given in % of tube wall) Is there a specification the standard needs to comply with? (ASME, etc.) If you have a drawing, or even a simple hand sketch, please send that along as well. We specialize in custom eddy current tubes, and have years of experience in machining a huge range of defects. From TWHs and FBHs, OD and ID grooves, milled flats, and OD and ID thinning bands, to ID FBHs, ID contoured flats, 120°/180° wearscars, tapered flaws, and tube-to-tube wear,

Application

Description

IRIS

Comments

Heat Exchangers

Nonferromagnetic material Stainless steel, Cu/Ali

X

– ECT is the recommended choice for its speed and accuracy.- IRIS can sometimes be used to confirm the sizing of ID defects.

Mildly ferromagnetic material Duplex steel, SS439, Secure, Monel

X

– ECT is used only for thin tubes (<1.6 mm) with saturation probes.- For thicker walls, it is better to use RFT or MFL.- IRIS can sometimes be used to confirm the sizing of defects.

Ferromagnetic material Carbon steel, nickel. Typical defects are pitting and corrosion.

X

– RFT, MFL, and IRIS are good, and most of the time complementary.

Air Coolers

Carbon steel tube with aluminum fins Typical defects are ID pitting and OD wear close to the water box.

X

– RFT is not effective because the fins disturb the remote field.- MFL is quick and sensitive but does not allow sizing.- IRIS is often used to back up MFL but has difficulty with OD flaws.

Boilers

Carbon steel tube Typical defects are pitting, wear, and cracking at the tube sheet.

X

– RFT is good for wear detection and can easily pass the bend.- MFL is good only on straight boiler tubes without swages.- IRIS is good for wear and pits but has no sensitivity in the bend.

Internal Rotary Inspection System Tube Eddy Current Tube Standards. Ready to request a quote for a standard? Here's what we need... What is the material? (Alloy, OD and Wall) Is NDE supplying the material or will it be customer supplied? What defects are needed and what size? (most depths are given in % of tube wall) Is there a specification the standard needs to comply with? (ASME, etc.) If you have a drawing, or even a simple hand sketch, please send that along as well. We specialize in custom eddy current tubes, and have years of experience in machining a huge range of defects. From TWHs and FBHs, OD and ID grooves, milled flats, and OD and ID thinning bands, to ID FBHs, ID contoured flats, 120°/180° wearscars, tapered flaws, and tube-to-tube wear,
Ultrasonic Thickness Gauge NdeTech-UTG702 (NDETECH-UTG702)

Ultrasonic Thickness Gauge NdeTech-UTG702

Functions & Features        

  • Display: LCD with LED backlight .The brightness and the contrast of the LCD is adjustable.
  • Display contents: thickness value, coupling condition, power state, CAL calibration state, sound velocity.
  • Able to measure the ultrasonic velocity in turn if the thickness value is known in order to improve the measurement precision.
  • Zero adjustment: auto returning to zero when you press the key after the probe is put on the specimen.
  • Simply and easily operated.
  • Nonlinear correction, automatic compensation, in order to improve the measurement accuracy.
  • The test block of measuring sound velocity of known thickness.
  • Battery information indicates the rest capacity of the battery, Auto sleep and auto power off function to conserve battery life.
  • Optional software to process the memory data on the PC.
  • Alarm function: setting the measurement limit and alarming for the results beyond the limit.

Measuring Materials                 

  • Adapted to measure the thickness of good conductor for ultrasonic, such as metal (steel, cast iron, aluminum, copper), plastic, ceramic, glass, glass fiber and so on.

 

Technical Parameters

Measuring range(mm)

0.7~300

Resolution(mm)

0.01

Accuracy(mm)

±(0.5%H+0.04)mm,H is thickness

Velocity range(m/s)

1000~9999

Velocity measurement

Storage

500 Groups

Shell

Plastic

Operating temperature

-10~60

Dampness

20%~90%

Dimensions

130×70×25mm

Power supply

2 AAA alkaline batteries

Weight

200g

Standard Delivery

Main unit, Probes, Couplant bottle

Ultrasonic Thickness Gauge NdeTech-UTG702 Functions & Features • Display: LCD with LED backlight .The brightness and the contrast of the LCD is adjustable. • Display contents: thickness value, coupling condition, power state, CAL calibration state, sound velocity. • Able to measure the ultrasonic velocity in turn if the thickness value is known in order to improve the measurement precision. • Zero adjustment: auto returning to zero when you press the key after the probe is put on the specimen. • Simply and easily operated. • Nonlinear correction, automatic compensation, in order to improve the measurement accuracy. • The test block of measuring sound velocity of known thickness. • Battery information indicates the rest capacity of the battery, Auto sleep and auto power off function to conserve battery life. • Optional software to process the memory data on the PC. • Alarm function: setting the measurement limit and alarming for the results beyond the limit.
Per Page      1 - 6 of 6